Metrex Research: Professional-Grade Disinfection and Instrument Care
Metrex Research has long been a trusted name in healthcare and clinical settings, offering a focused line of surface disinfectants, high-level disinfectants, enzymatic instrument detergents, hand sanitizers, and concentration indicators. Whether you're outfitting a dental office, surgical center, endoscopy suite, or general healthcare facility, this collection brings together the core Metrex product families in one place — making it straightforward to find what your protocols call for.
Surface disinfectants and wipes: The CaviCide and CaviWipes families cover both liquid and wipe formats for quick, thorough surface decontamination. The CaviCide Surface Disinfectant Cleaner in a 1-gallon jug is a practical choice for facilities that need a reliable bulk-format option for wiping down equipment and hard surfaces.
High-level disinfectants: The MetriCide line includes glutaraldehyde-based and OPA-based formulations — MetriCide 28, MetriCide Plus 30, MetriCide OPA Plus — designed for reprocessing semi-critical instruments that require high-level disinfection.
Enzymatic instrument detergents: The MetriZyme line provides dual enzymatic cleaning for soaking and presoaking reusable instruments before disinfection or sterilization. Both the MetriZyme Dual Enzymatic Instrument Detergent and the MetriZyme Presoak Concentrate are available, giving facilities flexibility based on volume and workflow.
Concentration indicators: Proper high-level disinfection depends on verifying that glutaraldehyde solutions remain at effective concentrations. MetriTest strips are available for both 1.5% glutaraldehyde and 1.8% glutaraldehyde formulations, helping teams stay compliant with reprocessing protocols.
Hand sanitizer: The VioNexus Hand Sanitizer rounds out the collection for routine hand hygiene needs at the point of care.
How to Choose the Right Metrex Product for Your Setting
Start by identifying the task at hand. Surface disinfection — countertops, chair surfaces, equipment exteriors — is typically handled by CaviCide liquids or CaviWipes, with wipe formats offering added convenience for operatory turnovers. Instrument reprocessing requires a two-step approach: enzymatic cleaning first (MetriZyme), followed by high-level disinfection if the instrument is semi-critical. The right MetriCide formulation will depend on your facility's current protocol and the contact time required.
If your team uses glutaraldehyde-based disinfectants, pairing them with the appropriate MetriTest concentration indicator strips is an important part of a complete reprocessing workflow — always follow your facility's infection control guidelines and manufacturer instructions when selecting and using these products.
Built Around Clinical Workflows
What makes the Metrex Research line coherent as a collection is its focus on the full reprocessing and infection control cycle — from hand hygiene and surface disinfection through instrument cleaning and high-level disinfection verification. Facilities can source multiple steps
Frequently Asked Questions about Metrex Research
Metrex Research disinfectant products are used to clean, disinfect, and sterilize surfaces, instruments, and hands in clinical and healthcare settings. The Metrex Research line covers everything from high-level disinfectants for reusable medical instruments to surface wipes and hand sanitizers for everyday infection control.
Metrex Research infection control products are designed for healthcare professionals, dental offices, outpatient clinics, and surgical centers that require EPA-registered or high-level disinfection solutions. These products are intended for trained clinical staff who follow established infection prevention protocols rather than general household consumers.
Start by identifying whether your facility needs a surface disinfectant, a high-level disinfectant for reusable instruments, or an enzymatic detergent for instrument pre-soaking. Metrex Research offers distinct product categories for each use case, so matching the product type to your specific clinical workflow and regulatory requirements is the most reliable approach.
High-level disinfectants in the Metrex Research line are formulated to reprocess semi-critical reusable medical instruments by eliminating nearly all microorganisms, including bacterial spores at extended contact times. Surface disinfectants in the same line are designed for hard, non-porous environmental surfaces and are not intended for instrument reprocessing.
Start by diluting the enzymatic instrument detergent concentrate according to the manufacturer's instructions, then fully submerge soiled instruments and allow them to pre-soak for the recommended contact time. Enzymatic detergents work by breaking down protein, carbohydrate, and fat-based bioburden on instrument surfaces before terminal disinfection or sterilization.
Yes, a glutaraldehyde concentration indicator is necessary to confirm that a glutaraldehyde-based high-level disinfectant solution remains at or above its minimum effective concentration before each use. Regulatory guidelines and infection control standards require facilities to test reusable disinfectant solutions with an appropriate test strip to ensure patient safety.
Yes, Metrex Research produces alcohol-based disinfectant wipes that are formulated for use on hard, non-porous medical equipment surfaces and clinical contact surfaces. Always verify material compatibility with the equipment manufacturer before use, since alcohol-based wipes may not be suitable for all surface types or coatings.
Store Metrex Research high-level disinfectant solutions in their original, tightly sealed containers in a cool, well-ventilated area away from direct sunlight and heat sources. Once a solution is activated or diluted, it has a defined use-life that must be tracked and the solution must be discarded when concentration testing indicates it has fallen below the minimum effective concentration.
No, Metrex Research surface disinfectants cannot be substituted for high-level disinfectants when reprocessing semi-critical reusable medical instruments. Surface disinfectants are cleared for environmental surfaces only, and using them in place of a validated high-level disinfection process does not meet the clinical or regulatory standard required for instrument reprocessing.
Do you still have questions about Metrex Research?
If we still haven't answered your question, you can contact us by live chat or email and we will get back to you as soon as possible.